Sign in
Menu
Sign up
Docs
Azure compliance controlsAzure Database for PostgreSQL

PostgreSQL servers should have private endpoints enabled

Private endpoint connections enforce secure communication by enabling private connectivity to Azure Database for PostgreSQL. Configure a private endpoint connection to enable access to traffic coming only from known networks.

Private endpoint connections enforce secure communication by enabling private connectivity to Azure Database for PostgreSQL. Configure a private endpoint connection to enable access to traffic coming only from known networks and prevent access from all other IP addresses, including within Azure.

What this control checks

PostgreSQL servers should have private endpoints enabled

Common pitfalls

Only Approved connections pass the check

The existence condition requires privateLinkServiceConnectionState.status to equal Approved.

Effect can be set to Disabled

The effect parameter has a defaultValue of AuditIfNotExists. Its allowedValues are AuditIfNotExists and Disabled.

Audit evidence

Evidence that deployed resources meet this control: Azure Policy compliance results for the built-in policy definition "Private endpoint should be enabled for PostgreSQL servers" (0564d078-92f5-4f97-8398-b9f58a51f70b); PowerPipe control azure_compliance.control.postgres_server_private_link_used.

Framework-specific interpretation

NIST SP 800-53 Rev 5: Mapped to AC-17 (Remote Access), AC-17(1) (Monitoring and Control), AC-4 (Information Flow Enforcement) and 2 more clauses.

FedRAMP Moderate Baseline Rev 4: Mapped to AC-17 (Remote Access), AC-17(1) (Automated Monitoring/Control), AC-4 (Information Flow Enforcement) and 2 more clauses.

Framework mappings

The clauses this control is mapped to in each framework.

NIST SP 800-53 Rev 5

  • AC-17 Remote Access
  • AC-17(1) Monitoring And Control
  • Information Flow Enforcement (AC-4)
  • SC-7: Boundary Protection
  • SC-7(3) Access Points

FedRAMP Moderate Baseline Rev 4

  • AC-4 Information Flow Enforcement
  • AC-17 (3): Managed Access Control Points
  • AC-17(1) Automated Monitoring/Control
  • SC-7: Boundary Protection
  • SC-7(3) Access Points

NIST SP 800-171 Rev 2

  • 3.1.1 Limit system access to authorized users, processes acting on behalf of authorized users, and devices (including other systems)
  • 3.1.3 Control the flow of CUI in accordance with approved authorizations
  • 3.1.12: Monitor and control remote access sessions.
  • 3.1.13 Employ cryptographic mechanisms to protect the confidentiality of remote access sessions
  • 3.1.14 Route remote access via managed access control points
3 more clauses
  • 3.13.1: Monitor, control, and protect communications (i.e., information transmitted or received by organizational systems) at the external boundaries and key internal boundaries of organizational systems.
  • 3.13.2 Employ architectural designs, software development techniques, and systems engineering principles that promote effective information security within organizational systems
  • 3.13.5 Implement subnetworks for publicly accessible system components that are physically or logically separated from internal networks

CIS Azure Benchmark v4.0.0

  • 2.2.2.1 Ensure Private Endpoints are used to access {service}

CMMC 2.0 Level 2

  • AC.L1-3.1.1 Limit system access to authorized users, processes acting on behalf of authorized users, and devices (including other systems)
  • AC.L2-3.1.3 Control the flow of CUI in accordance with approved authorizations
  • AC.L2-3.1.12 Monitor and control remote access sessions
  • AC.L2-3.1.13 Employ cryptographic mechanisms to protect the confidentiality of remote access sessions
  • AC.L2-3.1.14 Route remote access via managed access control points
3 more clauses
  • SC.L1-3.13.1 Monitor, control, and protect communications (i.e., information transmitted or received by organizational systems) at the external boundaries and key internal boundaries of organizational systems
  • SC.L1-3.13.5 Implement subnetworks for publicly accessible system components that are physically or logically separated from internal networks
  • SC.L2-3.13.2 Employ architectural designs, software development techniques, and systems engineering principles that promote effective information security within organizational systems

FedRAMP High

  • AC-4 Information Flow Enforcement
  • AC-17 Remote Access
  • AC-17(1) Automated Monitoring / Control
  • SC-7 Boundary Protection
  • SC-7(3) Access Points

Tool mappings

Use these identifiers to cross-reference this control across tools, reports, and evidence.

  • Compliance.tf Control: postgres_server_private_link_used
  • Powerpipe Control: azure_compliance.control.postgres_server_private_link_used
  • Azure Policy Definition: 0564d078-92f5-4f97-8398-b9f58a51f70b

Last reviewed: 2026-10-14